Answers are grounded in this paper and cite their sources.
The design and fabrication of lithium niobate piezocomposite transducers aims to achieve high-temperature ultrasonic NDT measurements at 400ºC. In this paper, three aspects are investigated: exploring design parameters at room temperature by a comparison of experimental and modelled results for lithium niobate piezocomposites with an epoxy matrix; high-temperature electromechanical testing of lithium niobate piezocomposites with a cement matrix; and fabrication and testing of a high-temperature transducer operating at 400ºC for defect detection. The piezocomposites were made with a 1-3 structure using a y/36º-cut lithium niobate single-crystal material. The typical piezocomposite thickness was 1 mm, with a pillar width of 0.4-0.8 mm, a kerf width of 0.5 mm, a volume fraction of lithium niobate of 30-40% and a pillar aspect ratio (pillar height to pillar width) ranging from 1 to 6. The operating frequency of the samples was between 1 MHz and 4 MHz. The results of the lithium niobate piezocomposite with an epoxy matrix and pillar aspect ratios of 3, 4 and 6 indicated that a high coupling coefficient kt should be achievable, even with a low pillar aspect ratio. The piezocomposite material was heated in air to 400-500ºC over several thermal cycles and showed good stability of the electromechanical impedance spectrum. A 13 x 13 mm2 transducer with an operating frequency of 3 MHz was used to demonstrate the detection of an artificial defect in a steel block using a high-temperature couplant on a hot plate at 400ºC.
No takes yet. Share an insight, caveat, or question.
Kirk et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: