Key result
Endocardial pacemaker leads linked to underrecognized tricuspid stenosis via leaflet perforation.
Why the study?
Tricuspid stenosis related to endocardial pacemaker leads is rare and may be underrecognized, requiring clinical suspicion and Doppler echocardiography for diagnosis.
Case Report (n=2)
Tricuspid stenosis related to endocardial pacemaker and defibrillator leads may be underrecognized and requires clinical suspicion and Doppler echocardiography for diagnosis.
Answers are grounded in this paper and cite their sources.
Alerts clinicians to evaluate for lead perforation in paced patients with tricuspid stenosis; leaves open its true incidence and management.
Only four cases of tricuspid stenosis related to endocardial pacemaker leads have been reported. Two further cases associated with perforation of a tricuspid valve leaflet by a pacemaker lead are presented: a 46 year old woman and a 60 year old man. It is possible that tricuspid valve disease related to endocardial pacemaker and non-thoracotomy defibrillator leads is underrecognized. Diagnosis requires clinical suspicion and the use of Doppler echocardiography. Recent evidence of fibrosis affecting the tricuspid valve in hearts from patients who have had non-thoracotomy defibrillator implants suggests that this problem could be more common in the future.
No takes yet. Share an insight, caveat, or question.
David Heaven (2000) conducted a case report in Tricuspid stenosis related to endocardial pacemaker leads (n=2). Endocardial pacemaker leads was evaluated on Tricuspid stenosis associated with perforation of a tricuspid valve leaflet. Endocardial pacemaker leads can cause tricuspid stenosis through perforation of a tricuspid valve leaflet, a complication that may be underrecognized.
Synapse has enriched 10 related papers. Consider them for comparative context: