The electrical behavior and stability of a temperature sensor based on 4H-SiC Schottky diodes using Ni2Si as Schottky contact, are investigated. The ideality factor and the barrier height were found to be strongly dependent on the post-annealing temperature of the Ni contact (which lead to the formation of Ni2Si). A nearly ideal Schottky device, with the barrier height approaching the high value of 1.7eV, and a slight temperature dependence, was obtained after an annealing at TA=800°C. This high barrier height proves that Ni2Si is suitable as Schottky contact for temperature sensors, able to reliably operate up to 450°C. Sensor sensitivity levels between 1.00mV/°C and 2.70 mV/°C have been achieved.