Key result
ECG biometric recognition via smart textiles achieves ~97% accuracy using a support vector machine.
Why the study?
Most ECG biometric research uses medical-grade sensors in clinical settings, which is unrealistic for wearable ECG-based biometric applications in real life.
Observational (n=22)
No
ECG biometrics using commercially available smart textile shirts and machine learning classifiers can achieve high recognition accuracy in real-life scenarios.
High accuracy on smart textiles supports real-world ECG biometrics feasibility; leaves open prospective validation in larger cohorts.
The rapid proliferation of wearable applications and technologies capable of acquiring biomedical signals has prompted the incorporation of biomedical signals, such as the electrocardiogram (ECG), for biometric purposes in wearable platforms. Most ECG biometric research utilises medical-grade sensors in clinical settings, which is unrealistic for wearable ECG-based biometric applications in the real world. Therefore, this research aims to examine the ECG biometric on smart textile garments in real life, collected from commercially available wearable Hexoskin Proshirt and HeartIn Fit shirts. ECG data were obtained from 22 participants who took part in this study. The raw ECG signal is initially pre-processed using noise-removal Butterworth filters in the time domain, followed by an effective QRS segmented feature extraction technique. Finally, around 2076 datasets were created for training and validation, while the remaining 501 datasets were employed to test the suggested recognition approach with 29 Machine Learning Classifiers. Subsequently, Quadratic SVM has the highest accuracy at 96.8% for ECG biometrics, followed by Narrow Neural Network with 95.8% and Wide Neural Network with 95.4%. Further improvement to the QSVM parameter improved the accuracy to 97.4% with an error rate of 2.6%, followed by a sensitivity of 97.4% with a precision of 97.7% and a false rejection rate of 2.6%. Thus, the results of this study further validate the feasibility of applying ECG biometrics for recognition in real-life scenarios utilising a smart textile shirt with different configurations and brand is possible.
No takes yet. Share an insight, caveat, or question.
Nawawi et al. (2023) conducted an observational in Healthy participants (n=22). Smart textile garments (Hexoskin Proshirt and HeartIn Fit shirts) was evaluated on Biometric recognition accuracy. ECG biometric recognition using smart textile garments achieved an accuracy of 97.4% and a false rejection rate of 2.6% when utilizing a Quadratic Support Vector Machine classifier.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: