Answers are grounded in this paper and cite their sources.
In 109 consecutive patients suspected of having gastro-oesophageal reflux (GOR) a 3.5-h pH-monitoring in the oesophagus was performed during the daytime. The data were stored in a portable recording system, and three different variables (mean pH, mean acid clearance rate, and number of spikes) were calculated. Compared with a combined endoscopic-histologic score for the diagnosis of oesophagitis, assumed to be due to GOR, the 3.5-h pH-monitoring had a sensitivity of 85% and a specificity of 81%. The data suggest that the short-term pH-monitoring is almost as accurate as the traditional 24-h pH-monitoring and more convenient both for the patient and the gastroenterologic unit.
No takes yet. Share an insight, caveat, or question.
Jørgensen et al. (1988) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: