Answers are grounded in this paper and cite their sources.
This study investigates the corrosion rate of low-carbon steel ASTM A36 and AISI 1020 in sulfuric acid solution under varying heat treatment temperatures and immersion times. Samples were subjected to heat treatment at 600, 820, and 1100 °C, followed by immersion for 24, 48, and 72 hours. The results reveal significant effects of heat treatment temperature and immersion duration on corrosion performance. At 600 °C with a 72-hour immersion, ASTM A36 exhibited a corrosion rate of 140.68 mm/year, while AISI 1020 showed 149.07 mm/year. At 820 °C, the corrosion rates for ASTM A36 and AISI 1020 were 102.34 mm/year and 96.48 mm/year, respectively. At 1100 °C, ASTM A36 demonstrated a corrosion rate of 87.97 mm/year, compared to 121.08 mm/year for AISI 1020. The findings highlight that increasing heat treatment temperature generally reduces the corrosion rate, though the effect varies by material.
No takes yet. Share an insight, caveat, or question.
Wiradinata et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: