Key result
Proposed nonparametric stepwise approach optimizes linear biomarker combinations to maximize AUC.
Why the study?
Existing methods for finding optimal linear combinations of biomarkers to maximize diagnostic accuracy may be overoptimistic due to evaluation methods, necessitating improved combination and validation approaches.
This paper reviews and proposes new linear combination methods for biomarkers to maximize AUC, using leave-one-pair-out cross-validation to avoid overoptimistic conclusions.
May aid optimal biomarker selection in diagnostics; leaves open external validation before clinical use.
Multiple diagnostic tests or biomarkers can be combined to improve diagnostic accuracy. The problem of finding the optimal linear combinations of biomarkers to maximise the area under the receiver operating characteristic curve has been extensively addressed in the literature. The purpose of this article is threefold: (1) to provide an extensive review of the existing methods for biomarker combination; (2) to propose a new combination method, namely, the nonparametric stepwise approach; (3) to use leave-one-pair-out cross-validation method, instead of re-substitution method, which is overoptimistic and hence might lead to wrong conclusion, to empirically evaluate and compare the performance of different linear combination methods in yielding the largest area under receiver operating characteristic curve. A data set of Duchenne muscular dystrophy was analysed to illustrate the applications of the discussed combination methods.
No takes yet. Share an insight, caveat, or question.
Kang et al. (2013) conducted a review in Duchenne muscular dystrophy. Nonparametric stepwise approach and leave-one-pair-out cross-validation vs. Existing methods (e.g., re-substitution method) was evaluated on Area under the receiver operating characteristic curve. A nonparametric stepwise approach and leave-one-pair-out cross-validation were proposed to find optimal linear combinations of biomarkers to maximize the area under the ROC curve.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: