Key result
Prone positioning triggers position-dependent tachyarrhythmia in a patient with a left-sided implantable venous access system.
Why the study?
Position-dependent tachyarrhythmia following prone positioning in patients with totally implantable venous access systems (TIVAS) is not well described.
Prone positioning in patients with a totally implantable venous access system can induce position-dependent tachyarrhythmias.
Prone positioning may trigger tachyarrhythmias in patients with totally implantable venous access systems; leaves open need for prospective confirmation before practice change.
Summary We present a case report of position‐dependent tachyarrhythmia following prone positioning for surgery in a 42‐yr‐old female with a left‐sided totally implantable venous access system (TIVAS) in‐situ. TIVASs are becoming increasingly popular for cancer patients receiving chemotherapy and who may present for either elective or emergency surgery.
No takes yet. Share an insight, caveat, or question.
Suhail et al. (2014) studied this question. Prone positioning during surgery induced a position-dependent tachyarrhythmia in a patient with a left-sided totally implantable venous access system.