The content of Bromhexine HCl in pharmaceutical formulation was determined using adsorptive stripping voltammetry with a glassy carbon electrode (GCE) modified by electrochemical reduced graphene oxide (ErGO/GCE). The results revealed that the electrochemical oxidation of bromhexine HCl on the ErGO/GCE electrode is an irreversible process and adsorptive on the surface of the electrode. The optimal conditions included Britton–Robinson buffer at pH 5.5, an accumulation potential of 0 V, an accumulation time of 60 s, a scan rate of 0.025 V/s, and a linear concentration range from 1 × 10–8 to 5 × 10–6 mol L–1. The method demonstrated high sensitivity with a limit of detection (LOD) of 2.7 × 10–9 mol L–1 and a limit of quantification (LOQ) of 9 × 10–9 mol L–1. It exhibited good repeatability with a relative standard deviation (RSD) of less than 5%, and high accuracy with recovery values ranging from 96 to 105%. The method was successfully applied to the determination of Bromhexine HCl in pharmaceutical formulations.