Key result
Adductor pollicis muscle thickness accurately identifies nutritional risk versus SGA with an AUC of ~0.82.
Why the study?
The relationship between adductor pollicis muscle thickness and subjective global assessment for nutritional risk in cardiac intensive care patients was not established.
Does adductor pollicis muscle thickness accurately assess nutritional risk compared to subjective global assessment in cardiac ICU patients?
Cross-Sectional (n=83)
No
Does adductor pollicis muscle thickness accurately assess nutritional risk compared to subjective global assessment in cardiac ICU patients?
Effect estimate: AUC 0.822
Adductor pollicis muscle thickness is an accurate and practical method for evaluating nutritional risk in cardiac intensive care unit patients.
OBJECTIVE: To verify the relationship between the adductor pollicis muscle thickness test and the subjective global assessment and to correlate it with other anthropometric methods. METHODS: This observational cross-sectional study was conducted in the intensive care unit of a cardiology hospital in the state of Rio Grande do Sul, Brazil. The hospitalized patients underwent subjective global assessment and adductor pollicis muscle thickness tests on both hands, along with measurement of the right calf circumference. Laboratory parameters, length of stay, vital signs and electronic medical record data and tests were all collected. RESULTS: The study population included 83 patients, of whom 62% were men. The average age was 68.6 ± 12.5 years. The most common reason for hospitalization was acute myocardial infarction (34.9%), and the most common pathology was systolic blood pressure (63.9%), followed by diabetes mellitus (28.9%). According to subjective global assessment classifications, 62.7% of patients presented no nutritional risk, 20.5% were moderately malnourished and 16.9% were severely malnourished. Women had a higher nutritional risk, according to both the subjective global assessment and the adductor pollicis muscle thickness test, the cutoff for which was < 6.5mm (54.8%; p = 0.001). The pathology presenting the greatest nutritional risk was congestive heart failure (p = 0.001). Evaluation of the receiver operating characteristic (ROC) curve between adductor pollicis muscle thickness and subjective global assessment showed the accuracy of the former, with an area of 0.822. CONCLUSION: Adductor pollicis muscle thickness proved to be a good method for evaluating nutritional risk.
No takes yet. Share an insight, caveat, or question.
Karst et al. (2015) conducted a cross-sectional in Hospitalized in a cardiac intensive care unit (n=83). Adductor pollicis muscle thickness test vs. Subjective global assessment was evaluated on Accuracy of adductor pollicis muscle thickness compared to subjective global assessment (AUC 0.822). Adductor pollicis muscle thickness accurately identified nutritional risk compared to subjective global assessment, with an area under the ROC curve of 0.822.