Double-resonance optically pumped magnetometers are attractive instruments for unshielded magnetic field measurements, such as geophysical surveying and archaeology, due to their wide dynamic range and high sensitivity. However, conventionally these are s00exc00exa00exl00exa00exr devices, measuring only the field's total magnitude. Through modeling and laboratory demonstration, the authors show that the amplitude and phase of first- and second-harmonic signals contain enough information to measure a static magnetic field's magnitude a00exn00exd $o{{0}{0ex}}r{{0}{0ex}}i{{0}{0ex}}e{{0}{0ex}}n{{0}{0ex}}t{{0}{0ex}}a{{0}{0ex}}t{{0}{0ex}}i{{0}{0ex}}o{{0}{0ex}}n$. This is all achieved through improved signal analysis, allowing the technique to be implemented in practical sensors without additional hardware.
No takes yet. Share an insight, caveat, or question.
Ingleby et al. (2018) studied this question.