Answers are grounded in this paper and cite their sources.
This paper presents the design, fabrication, and testing of a piezoelectric parametric frequency increased generator for harvesting low-frequency non-periodic vibrations. The generator incorporates a bulk piezoelectric ceramic machined using ultrafast laser ablation. The electromechanical transducer is designed as a clamped-clamped spiral beam in order to decrease the stiffness within a limited footprint. An internal mechanism up-converts the ambient vibration frequency to a higher internal operation frequency in order to achieve better electromechanical coupling and efficiency. To gain maximum power output, the optimum width and thickness values of a spiral up-conversion unit are computed via multi-physics finite-element analysis simulations. The fabricated device generated a peak power of 100 μW and an average power of 3.25 μW from an input acceleration of 9.8 m/s2at 10 Hz. The device operates over a frequency range of 24 Hz. The internal volume of the generator is 1.2 cm3.
No takes yet. Share an insight, caveat, or question.
Galchev et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: