Answers are grounded in this paper and cite their sources.
A hybrid heat sink design with microchannels and stepped pin-fins is introduced for the hotspot-targeted thermal management of microprocessors. The thermal and hydraulic performance were assessed numerically and compared to that of a hybrid heat sink with uniform pin-fins. Both hybrid heat sinks were designed to have two zones using rectangular microchannels above the processor’s background area and an array of pin-fins (stepped and uniform pin-fins) over the hotspot area. Conjugate heat transfer analysis was performed with the entire heat sink as the computational domain by solving the three-dimensional Navier-Stokes and energy equations. The hybrid heat sink with stepped pin-fins exhibited remarkable improvement in the temperature uniformity at the hotspot as compared to the one with uniform pin-fins, along with ample improvements in the thermal resistance, maximum temperature rise at the hotspot, and pumping power. A parametric investigation was also performed for the hybrid heat sink with uniform pin-fins to find an optimum geometry based on two geometric parameters: the ratio of the diameter of the pin-fins to their pitch and the total number of pin-fins in the array. The results revealed improvements in the thermal performance, but the pumping power was increased.
No takes yet. Share an insight, caveat, or question.
Ansari et al. (2019) studied this question.