Answers are grounded in this paper and cite their sources.
A rotating-cylinder viscometer was used to measure the viscosity of fayalite-based melts from 1200 to 1350°C. The silica content and oxygen pressure were in the range of 22.5 to 37.5 weight per cent and 10−7 to 10-11 atmospheres. To illustrate their effects, three-dimensional viscosity surfaces were plotted at various temperatures. Viscosities generally decreased with increasing temperature, increasing oxygen pressure and decreasing silica content. However, a maximum was found near the fayalite composition. Added CaO decreased viscosity. Résumé Un viscosimètre à cylindre tournant a été utilisé pour mesurer la viscosité entre 1200 et 1350°C de mélanges fondus à base de fayalite. La quantité de silice et la pression oxygène se situaient entre 22.5-37.5 pourcentage poids et 10−7-10−11 atmosphères respectivement. Afin d'illustrer leurs influences, les surfaces tridimensionnelles de viscosité sont portées en graphique à différentes températures. Les viscosités décroissent généralement avec l'augmentation de la temperature et de la pression oxygène et avec la diminution de la quantité de silice. Toutefois, on a trouve un maximum près de la composition de la fayalite. L'addition de CaO fait diminuer la viscosité.
No takes yet. Share an insight, caveat, or question.
Kaiura et al. (1977) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: