Key result
Power harmonic imaging is associated with better LV opacification and border visualization versus standard modalities.
Why the study?
The study aimed to compare the effects of three imaging modalities on left ventricular opacification and endocardial border definition using two different echo contrast agents in patients with suboptimal transthoracic images.
Does the choice of imaging modality or contrast agent improve left ventricular opacification and endocardial border definition in patients with suboptimal transthoracic images?
Observational (n=84)
Does the choice of imaging modality or contrast agent improve left ventricular opacification and endocardial border definition in patients with suboptimal transthoracic images?
Power harmonic imaging significantly improves left ventricular opacification and endocardial border visualization, effectively compensating for the use of a less robust contrast agent.
Answers are grounded in this paper and cite their sources.
Power harmonic imaging may enhance LV visualization in suboptimal echoes; leaves open whether it improves outcomes or warrants routine use.
AIMS: The purpose of this study was to prospectively compare the effect of three imaging modalities (fundamental, harmonics, and power harmonics) on left ventricular opacification and endocardial border definition with two different echo agents, Optison and Albunex. METHODS: A total of 84 patients who had suboptimal transthoracic images were studied with echo contrast agents Albunex (n=41) and Optison (n=43). Each contrast agent was examined with three different imaging modalities, fundamental, harmonics and power harmonics, respectively. Left ventricular opacification was obtained by videodensitometric analysis. Percentage of endocardial border visualization was determined by indexing circumference of visualized endocardium to total circumference. Variables were compared with respect to three imaging modalities between two different echo agents. RESULTS: Higher videointensities and higher percentages of endocardial visualization were achieved with Optison compared to Albunex with fundamental and harmonics. However, there was no significant difference between Optison and Albunex with respect to LV opacification and border visualization by power harmonics. CONCLUSION: These results indicate that left ventricular opacification and endocardial border visualization is significantly improved by using power harmonic imaging as compared to harmonics or fundamental imaging following both echo contrast agents. Furthermore, although Optison is clearly superior to Albunex in opacifying left ventricle, power harmonic imaging compensates for the less robust agent.
No takes yet. Share an insight, caveat, or question.
Melda S. Dolan (2001) conducted an observational in suboptimal transthoracic images (n=84). Optison vs. Albunex was evaluated on Left ventricular opacification and percentage of endocardial border visualization. Power harmonic imaging significantly improved left ventricular opacification and endocardial border visualization compared to harmonics or fundamental imaging for both Optison and Albunex.