Answers are grounded in this paper and cite their sources.
The performance of faster-than-Nyquist intensity modulation and direct detection (IM/DD) systems can be severely degraded by the inter-symbol interference (ISI) due to the component bandwidth limitation and the faster-than-Nyquist filtering. In addition, nonlinearities caused mainly by optical modulation and square-law detection can further deteriorate signal quality. Here, we propose to incorporate transmitter-side Tomlinson-Harashima precoding to mitigate the ISI and a Volterra nonlinear equalizer (VNLE) to mitigate the nonlinear distortions for PAM4 faster-than-Nyquist systems. We experimentally demonstrate a single wavelength 145 Gb/s PAM4 IM/DD transmission with bandwidth limited commercial components and sub-Nyquist sampling at 70 GSa/s. The optimal VNLE filter length is also investigated to balance the implementation complexity and system performance. In addition, compared with the scheme using transmitter-side duobinary precoding, receiver-side VNLE and maximum likelihood sequence estimation, both performance improvement and implementation complexity reduction are achieved.
No takes yet. Share an insight, caveat, or question.
Xiang et al. (2018) studied this question.