Key result
Low intraoperative carotid pressure ratio predicts impaired cerebral vascular reserve with 100% sensitivity.
Why the study?
The role of intravascular pressure ratio across carotid artery stenosis in assessing cerebral hemodynamics remains unclear.
Does carotid pressure ratio (CPR) measurement correlate with cerebral hemodynamics in patients undergoing carotid artery stenting for unilateral internal carotid artery stenosis?
Observational (n=25)
No
Does carotid pressure ratio (CPR) measurement correlate with cerebral hemodynamics in patients undergoing carotid artery stenting for unilateral internal carotid artery stenosis?
Intraoperative carotid pressure ratio (CPR) measurement using a pressure wire is a safe and feasible surrogate marker that correlates well with cerebral vascular reserve and can predict cerebral hemodynamic impairment in patients undergoing carotid artery stenting.
May support intraoperative CPR ≤0.80 to identify impaired cerebral reserve in CAS; leaves open prospective validation before practice change.
The role of intravascular pressure ratio across carotid artery stenosis in assessing cerebral hemodynamics remains unclear. This study evaluated the utility of pressure-wire-based carotid pressure ratio (CPR) measurement during carotid artery stenting (CAS) in patients with internal carotid artery (ICA) stenosis. We prospectively enrolled 25 patients undergoing CAS for unilateral ICA stenosis. CPR was defined as the ratio of mean arterial pressure distal to proximal to the stenosis, measured before and after CAS using a pressure wire. We analyzed the correlation of CPR with cerebral vascular reserve (CVR), cerebral blood flow asymmetry index (CBF-AI), and stenosis-related parameters. Receiver operating characteristic (ROC) analysis identified optimal CPR thresholds. CPR significantly correlated with CVR (R 2 = 0.38), CBF-AI, and stenosis severity. A CPR ≤ 0.80 accurately predicted impaired CVR (< 10%) with 100% sensitivity and 89% specificity. The CPR reached 1.0 when the minimal luminal diameter was ≥ 1.96 mm, suggesting resolution of the pressure gradient. No complications were observed with intraoperative CPR measurement. CPR measurement using a pressure wire is safe, minimally invasive, and reflects cerebral hemodynamic status. The CPR may complement imaging-based evaluation and support intra- and post-operative management in ICA stenosis. Further validation in larger multicenter cohorts is warranted.
No takes yet. Share an insight, caveat, or question.
Isozaki et al. (2025) conducted an observational in Internal carotid artery stenosis (n=25). Carotid pressure ratio (CPR) measurement was evaluated on Correlation of CPR with cerebral vascular reserve (CVR) (R2 = 0.38, p=<0.01). Intraoperative carotid pressure ratio significantly correlated with cerebral vascular reserve (R2 = 0.38), and a threshold of ≤ 0.80 predicted impaired reserve with 100% sensitivity and 89% specificity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: