Total and restricted energy loss rates are calculated for magnetic monopoles of charge $g=137e$ in Lexan polycarbonate. Range-energy curves are also presented. The restricted-energy-loss model is used to estimate the appearance of a monopole track in plastic detectors. The results are applied to the event observed by Price et al. and identified by them as a monopole. It is found that the observed etch rate is consistent with what one would expect for a slow magnetic monopole (β~0.5, $g=137e$). These results should also be of use to other investigators for both the design and analysis of monopole experiments.
No takes yet. Share an insight, caveat, or question.
S. P. Ahlen (1976) studied this question.