Case report demonstrates successful bioresorbable ductal stenting in a newborn with critical pulmonary stenosis, highlighting a potential temporary bridge for duct-dependent circulation.
BACKGROUND: Critical pulmonary valve stenosis is a rare congenital heart defect that causes cyanosis in the newborn and is characterized by severe narrowing of the right ventricular outflow tract and pulmonary valve, leading to restricted pulmonary blood flow. FIRST-IN-HUMAN/EARLY REPORTS SUMMARY: We present the case of a full-term male infant diagnosed with critical pulmonary stenosis with ductal-dependent pulmonary circulation. The patient underwent successful percutaneous pulmonary valvuloplasty and ductal stenting with a new iron-based bioresorbable stent (IBS Angel, Biotyx Medical). Postoperative evaluation was favorable. DISCUSSION: This combined strategy ensured effective right ventricular decompression and maintenance of pulmonary blood flow. NOVELTY: This is to our knowledge the first case in Europe on the use of a bioresorbable stent to maintain ductal patency in critical pulmonary stenosis with dual pulmonary blood supply. TAKE-HOME MESSAGES: Bioresorbable stents may represent a safe short- to medium-term option in selected neonates with ductal-dependent pulmonary circulation. Early outcomes appear favorable, but longer follow-up is warranted.
No takes yet. Share an insight, caveat, or question.
Barsali et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: