Answers are grounded in this paper and cite their sources.
Frequency-modulated continuous-wave (FMCW) laser interferometric ranging technology, characterized by strong anti-interference capability and no need for cooperative reflection targets, holds significant application value in large-space precision measurements. Enhancing its accuracy and stability is currently a core demand. This paper proposes an innovative FMCW ranging scheme: integrating femtosecond optical frequency comb calibration with a two-speed frequency sweeping strategy. System calibration is completed via the slow-speed sweep, while precision ranging is achieved through dual fast-speed sweeps, simultaneously addressing the issue of frequency sweep nonlinearity and Doppler vibration. While improving measurement speed, the ranging standard deviation within 38 m is reduced to below 7 µm, providing what we believe is a new path for optimizing FMCW ranging accuracy.
No takes yet. Share an insight, caveat, or question.
Ma et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: