Answers are grounded in this paper and cite their sources.
Axial magnetic bearing actuators often lack the bandwidth necessary to achieve the desired closed loop performance due to their nonlaminated construction. Since bandwidth can be directly related to actuator material and geometric properties, an opportunity exists to improve closed loop performance through the optimization of these properties. This prospect is exploited herein, both to demonstrate the improvements that can be obtained and to illustrate the relationship between various parameters and dynamic performance. For the latter, Pareto-optimal curves are generated exploring the influence that disk outer radius, peak force, axial gap, and magnetic permeability have upon actuator bandwidth.
No takes yet. Share an insight, caveat, or question.
Spece et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: