Key result
Fontan graft selection does not affect systemic pressures and flows, but anastomosis placement alters hepatic distribution.
Why the study?
Patient-specific multiscale modeling can simulate virtual Fontan surgeries to predict post-operative hemodynamics and inform clinical decision support.
Does graft selection (ECC vs 9mm Y-graft vs 12mm Y-graft) affect systemic hemodynamics and hepatic flow distribution in patients undergoing the Fontan procedure?
Does graft selection (ECC vs 9mm Y-graft vs 12mm Y-graft) affect systemic hemodynamics and hepatic flow distribution in patients undergoing the Fontan procedure?
Systemic pressures and blood flow after the Fontan procedure are determined by patient pulmonary vascular impedance and anastomosis placement, rather than graft selection.
Answers are grounded in this paper and cite their sources.
Graft selection may not dictate Fontan hemodynamics; leaves open prospective validation of anastomosis-focused modeling.
Objectives Patient-specific multiscale modeling simulates virtual surgeries of the Fontan procedure using three different graft options. Predictive modeling details post-operative outcomes that can help inform clinical decision support. Methods Six patients underwent preoperative cardiac magnetic resonance imaging and catheterization. Virtual surgery is carried out for each patient to test the resulting hemodynamics of three Fontan graft options: ECC, 9mm Y-graft, and 12mm Y-graft. Results 1) one-way ANOVA p>0.998 in all systemic pressures and flows between graft options, 2) p=0.706 for hepatic flow distribution between graft options, 3) local power loss differences do not affect the systemic circulation, 4) anastomosis positioning modification of the same Y-graft in the same patient changed left PA hepatic distribution from 0.66 to 0.49 Conclusions Systemic pressures and blood flow after the Fontan procedure are not affected by graft selection but are well influenced by patient pulmonary vascular impedance. The hepatic distribution can be affected by anastomosis placement. Ultra-mini abstract We present the first case series of patient-specific multiscale modeling of the Fontan procedure. Despite noticeable local power loss differences, graft selection does not affect systemic pressure and flow rates or other clinically relevant quantities. Anastomosis placement can affect hepatic distribution.
No takes yet. Share an insight, caveat, or question.
Kung et al. (2021) studied Single ventricle circulation (n=6). Fontan graft options (ECC, 9mm Y-graft, 12mm Y-graft) vs. Comparison among graft options was evaluated on Systemic pressures and flows (p=>0.998). Patient-specific multiscale modeling demonstrated that Fontan graft selection does not significantly affect systemic pressures and flows (p>0.998), though anastomosis placement can alter hepatic distribution.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: