OBJECTIVE: The objective of this study was to present the outcome of the internal limiting membrane (ILM) peeling flap technique for a treatment-naïve, flat edge (Type II), full-thickness macular hole (MH). METHODS: A 52-year-old man presented with complaints of decreased vision and seeing black spot. He was diagnosed to have a flat edge, full-thickness MH, which was confirmed by optical coherence tomography (OCT). He underwent 23G vitrectomy with brilliant blue G-assisted inverted ILM peeling with an inverted flap over the hole followed by fluid gas exchange. RESULTS: Postoperative follow-up until 3 months showed successful closure of the MH, which was confirmed by OCT. The best-corrected visual acuity improved from baseline 6/60 to 6/12 at the final follow-up. CONCLUSION: Using the inverted ILM flap technique, a treatment-naïve, flat edge (Type II), full thickness MH achieved successful anatomical and functional outcomes.