Key result
Theophylline increases cellular extract fluorescence ~11-fold upon riboswitch activation in a FRET-based optical assay.
Why the study?
Creation of synthetic riboswitches to novel ligands depends on the ability to monitor riboswitch activation in the presence of analyte.
Effect estimate: 11-fold increase
The eGFP-REACh FRET pair provides an improved signal-to-noise ratio for monitoring riboswitch activation in E. coli.
Enables sensitive extract-based riboswitch monitoring; extends biosensor engineering but leaves in vivo and clinical translation open.
Riboswitches are regulatory RNAs located in the 5'-untranslated region of mRNA sequences that recognize and bind to small molecules and regulate the expression of downstream genes. Creation of synthetic riboswitches to novel ligands depends on the ability to monitor riboswitch activation in the presence of analyte. In our work, we have coupled a synthetic riboswitch to an optical reporter assay based on fluorescence resonance energy transfer (FRET) between two genetically encoded fluorescent proteins. The theophylline-sensitive riboswitch was placed upstream of the Tobacco Etch Virus (TEV) protease coding sequence. Our FRET construct was composed of eGFP and a nonfluorescent yellow fluorescent protein mutant called REACh (for resonance energy-accepting chromoprotein) connected with a peptide linker containing a TEV protease cleavage site. Addition of theophylline to the E. coli cells activates the riboswitch and initiates the translation of mRNA. Synthesized protease cleaves the linker in the FRET-based fusion protein causing a change in the fluorescence signal. By this method, we observed an 11-fold increase in cellular extract fluorescence in the presence of theophylline. The advantage of using an eGFP-REACh pair is the elimination of acceptor fluorescence. This leads to an improved detection of FRET via better signal-to-noise ratio, allowing us to monitor riboswitch activation in a wide range of analyte concentrations from 0.01 to 2.5 mM.
No takes yet. Share an insight, caveat, or question.
Harbaugh et al. (2009) studied this question. FRET-based optical assay with eGFP-REACh pair and theophylline-sensitive riboswitch was evaluated on Cellular extract fluorescence (11-fold increase). A FRET-based optical assay using an eGFP-REACh pair demonstrated an 11-fold increase in cellular extract fluorescence upon riboswitch activation by theophylline.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: