Answers are grounded in this paper and cite their sources.
Background: As a result of advances in adjuvant therapy, the 5-year survival rate of malignant bone tumors has increased from 20% to 70% .Similarly, longer survival times are observed as a result of advances in medical treatment of metastatic cancer patients.In addition, after lungs and livers, bones are the third most common site of metastasis in cancer patients.Therefore, reconstruction with modular tumor resection prostheses is increasingly used.In addition, the reported complication rates are five to ten times higher than those seen in normal joint arthroplasty.In this article, we present a non-traumatic fracture of a modular tumor resection prosthesis (ESTAS Medical, Sivas, Turkey) at the junction of the intramedullary nail and the prosthesis interconnection.No similar mechanical complication cases of this prosthesis were reported in the literature we reviewed.Case Description: A 73-year-old (82 kg, 163 cm, Body mass index: 30.86) female patient was admitted to the emergency department with complaints of hip pain and inability to walk.Due to the pathological fracture in the subtrochanteric region, proximal femur resection and reconstruction with tumor prosthesis were performed.The reconstruction was performed with a partial cementless modular tumor prosthesis (ESTAS Medical, Sivas, Turkey).During the follow-up, the patient was mobilized with a single cane and had no pain.In the 2nd year postoperatively, a non-traumatic fracture was observed between the femoral intramedullary nail and the prosthesis interconnection area.The fractured prosthesis area was reached by approaching the fracture site at the appropriate level over the old incision area, and revision surgery was performed by replacing the intracanal femoral nail and the interconnection segment piece.There was no wound site problem in the patient and he was mobilized with support. Conclusion:The modular structure of tumor resection prostheses, which are increasingly used, has many advantages, as well as a potential mechanical weakness as a result of the impressions we have obtained.With the advances in adjuvant treatments and the prolongation of survival, this mechanical weakness may lead to more complications.New designs and studies to eliminate this mechanical weakness, especially in the joints of the prosthesis, are highly needed.
No takes yet. Share an insight, caveat, or question.
Gunay et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: