Key result
Optimal exercise SPECT-MPI detects significant graft stenosis one year post-CABG with ~77% sensitivity.
Why the study?
The value of SPECT-MPI for detecting graft disease after CABG has not been studied prospectively in an unselected cohort.
Does SPECT-MPI accurately detect coronary artery bypass graft disease compared to coronary angiography in patients one year post-CABG?
Cohort (n=79)
Double-blind
No
Does SPECT-MPI accurately detect coronary artery bypass graft disease compared to coronary angiography in patients one year post-CABG?
Effect estimate: Sensitivity 77%, Specificity 69%, Accuracy 73% (optimal exercise)
SPECT-MPI demonstrates good sensitivity and accuracy for detecting graft disease one year post-CABG, provided optimal stress conditions are achieved.
May inform post-CABG graft surveillance under optimal conditions; leaves open need for prospective validation before practice change.
BACKGROUND: The value of single photon emission computed tomography stress myocardial perfusion imaging (SPECT-MPI) for detecting graft disease after coronary artery bypass surgery (CABG) has not been studied prospectively in an unselected cohort. METHODS: Radial Artery Versus Saphenous Vein Graft Study is a Veterans Affairs Cooperative Study to determine graft patency rates after CABG surgery. Seventy-nine participants agreed to SPECT-MPI within 24 hours of their coronary angiogram, one-year after CABG. The choice of the stress protocol was made at the discretion of the nuclear radiologist and was either a symptom-limited exercise test (n = 68) or an adenosine infusion (n = 11). The SPECT-MPI results were interpreted independent of the angiographic results and estimates of sensitivity, specificity and accuracy were based on the prediction of a graft stenosis of ≥70% on coronary angiogram. RESULTS: A significant stenosis was present in 38 (48%) of 79 patients and 56 (22%) of 251 grafts. In those stress tests with an optimal exercise heart rate response (>80% maximum predicted heart rate) (n = 26) sensitivity, specificity and accuracy of SPECT-MPI for predicting the graft stenosis was 77%, 69% and 73% respectively. With adenosine (n = 11) it was 75%, 57% and 64%, respectively. Among participants with a suboptimal exercise heart rate response, the sensitivity of SPECT-MPI for predicting a graft stenosis was <50%. The accuracy of SPECT-MPI for detecting graft disease did not vary significantly with ischemic territory. CONCLUSIONS: Under optimal stress conditions, SPECT-MPI has a good sensitivity and accuracy for detecting graft disease in an unselected patient population 1 year post-CABG.
No takes yet. Share an insight, caveat, or question.
Aloul et al. (2012) conducted a cohort in Coronary artery bypass graft disease (n=79). Single Photon Emission Computed Tomography stress myocardial perfusion imaging (SPECT-MPI) vs. Coronary angiography was evaluated on Detection of graft stenosis ≥70% on coronary angiogram (Sensitivity 77%, Specificity 69%, Accuracy 73% (optimal exercise)). In patients one year post-coronary artery bypass graft surgery, SPECT-MPI with optimal exercise stress demonstrated a sensitivity of 77% and accuracy of 73% for detecting significant graft stenosis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: