The threshold-voltage ( V th ) shift of 4H-SiC MOSFETs with Ar or N 2 O post-oxidation annealing (POA) was measured by conventional sweep and non-relaxation methods. Although the V th shift values of both samples were almost identical when measured by the sweep method, those for the Ar POA samples were larger than those for the N 2 O POA samples when measured by the non-relaxation method. Thus, we can say that investigating the exact V th shifts using only the conventional sweep method is difficult. The temperature-dependent analysis of the V th shifts measured by both methods revealed that the N 2 O POA decreases charge trapping in the near-interface region of the SiO 2 .
No takes yet. Share an insight, caveat, or question.
Sometani et al. (2016) studied this question.