Percutaneous basket retrieval under fluoroscopy and TEE successfully extracts a large mobile RA thrombus.
Answers are grounded in this paper and cite their sources.
Demonstrates the feasibility of percutaneous removal of a large right atrial thrombus using a basket retrieval device under imaging guidance.
This report documents the removal of a large mobile serpiginous right atrial thrombus using percutaneous intravascular techniques with fluoroscopic and transesophageal echocardiographic guidance. Technical aspects and potential complications are discussed.
No takes yet. Share an insight, caveat, or question.
Mukharji et al. (2000) studied this question. Percutaneous removal using a basket retrieval device under fluoroscopic and transesophageal echocardiographic guidance successfully extracted a large mobile right atrial thrombus.