Key result
Camera-based meditation system estimates activity and respiratory rate with ~1.75 BPM mean absolute error.
Why the study?
A camera-based meditation evaluation system is needed to help meditators improve performance by measuring breathing characteristics and body movement.
Observational (n=17)
A smartphone camera-based system can estimate respiratory rate during meditation with a mean absolute error of 1.75 BPM.
Hypothesis-generating for contactless RR monitoring in meditation; requires prospective validation before clinical use.
Meditation practice is mental health training. It helps people to reduce stress and suppress negative thoughts. In this paper, we propose a camera-based meditation evaluation system, that helps meditators to improve their performance. We rely on two main criteria to measure the focus: the breathing characteristics (respiratory rate, breathing rhythmicity and stability), and the body movement. We introduce a contactless sensor to measure the respiratory rate based on a smartphone camera by detecting the chest keypoint at each frame, using an optical flow based algorithm to calculate the displacement between frames, filtering and de-noising the chest movement signal, and calculating the number of real peaks in this signal. We also present an approach to detecting the movement of different body parts (head, thorax, shoulders, elbows, wrists, stomach and knees). We have collected a non-annotated dataset for meditation practice videos consists of ninety videos and the annotated dataset consists of eight videos. The non-annotated dataset was categorized into beginner and professional meditators and was used for the development of the algorithm and for tuning the parameters. The annotated dataset was used for evaluation and showed that human activity during meditation practice could be correctly estimated by the presented approach and that the mean absolute error for the respiratory rate is around 1.75 BPM, which can be considered tolerable for the meditation application.
No takes yet. Share an insight, caveat, or question.
Kashevnik et al. (2021) conducted an observational in Meditation practice (n=17). Camera-based meditation evaluation system was evaluated on Mean absolute error for respiratory rate. A camera-based meditation evaluation system correctly estimated human activity and respiratory rate during meditation practice with a mean absolute error of 1.75 BPM.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: