For individual calibration and testing events, no third-party assessments are conducted on the validity of measuring instrument calibrations, personnel qualifications, or the appropriateness of measurement conditions in current calibration and testing practices, as is done during accreditation review audits. Since performing such assessments manually can be labor-intensive for human reviewers and prone to errors, we have developed a system for the automatic validation of digitized data, working alongside the current accreditation system. This system is designed for the documented records of the calibration of a reference photovoltaic device. The system incorporates three key functions: data packaging, automatic validation, and auditable log by the means of the blockchain system. Specifically, all data related to the calibration of an item is packaged by an application, the extracted data from the package is validated by programs, and the validation logs are stored securely without tampering. This system can support quality compliance in calibration and testing processes.