Key result
Rewiring, balloon re-expansion, and a second valve successfully resolve TAVI migration and stent infolding.
Why the study?
Accidental valve malpositioning during transcatheter aortic valve implantation can occur despite high procedural safety, requiring detailed reporting of complications.
Case Report (n=1)
No
Transcatheter valve migration and frame infolding during TAVI is a rare, life-threatening complication that can be successfully managed by rewiring, balloon re-expansion, and deployment of a second valve.
Rare TAVI valve convolution after migration warrants procedural vigilance; leaves open optimal prevention and retrieval strategies.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Verhemel et al. (2023) conducted a case report in Critical aortic stenosis (n=1). Transcatheter aortic valve implantation (TAVI) was evaluated on Resolution of transcatheter heart valve migration and stent infolding. Transcatheter heart valve migration and stent infolding during TAVI was successfully managed by rewiring the infolded frame, balloon re-expansion, and deployment of a second valve.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: