Monitoring the effectiveness of sanitization by clean in place (CIP) systems is essential to controlling the microbiological condition of a process and a product. This study was conducted to compare current conventional methodology with the impedance methodology. The impedance method is a “rapid” methodology that effectively addresses one of the major problems with conventional plating methods—the time required from sampling to results. The method currently used is membrane filtration of the sample and plating on an agar medium and anaerobic incubation at 30°C for five days. The impedance method evaluated during this study was able to predict a negative sample within 36 hr of processing the sample. Positive samples were detectable beginning at 5 hr. This reduction in time was accomplished without a reduction in sensitivity. The impedance method described in this study offers a rapid alternative to conventional plating methodology, which is normally used to evaluate the effectiveness of cleaning systems.