Key result
Dedicated TAVI guidewire achieves 100% procedural safety with no wire displacement.
Why the study?
The safety and performance of a specifically designed, dedicated TAVI guidewire had not been previously evaluated in humans.
Is a specifically designed, dedicated TAVI guidewire safe and feasible for patients undergoing transcatheter aortic valve implantation?
Observational (n=39)
Open-label
No
Is a specifically designed, dedicated TAVI guidewire safe and feasible for patients undergoing transcatheter aortic valve implantation?
A dedicated TAVI guidewire is safe and feasible for transcatheter aortic valve implantation, demonstrating no procedural or pericardial complications in this first-in-man study.
Supports initial feasibility of dedicated TAVI guidewire; leaves open need for randomized trials to confirm safety and performance.
AIMS: The aim of this study was to evaluate the safety and performance of a specifically designed, dedicated TAVI guidewire. METHODS AND RESULTS: From May 2011 to August 2012, 39 consecutive patients referred for TAVI were prospectively enrolled in a first-in-man, open label, non-randomised feasibility study to evaluate the safety and performance of a specifically designed, dedicated TAVI guidewire in our institution (mean age 80.4±5.1 years, mean logistic EuroSCORE 26.8±11.7%, n=29 CoreValve transfemoral, n=8 CoreValve direct aortic, n=1 Edwards SAPIEN valve direct aortic, n=1 CoreValve subclavian). The primary safety endpoint was reached successfully with the dedicated TAVI guidewire in all 39 cases with no cases of guidewire displacement from the left ventricle during the procedure. In three cases the wire was repositioned to optimise loop position using a pigtail catheter prior to valve implantation. There were no cases of guidewire-related procedural complications. The mean delivery system tracking time using the guidewire was 1.4±0.6 minutes and the mean deployment time for TAVI was 13.8±7.8 minutes. CONCLUSIONS: This represents the first recorded use of a dedicated TAVI guidewire to treat patients with a transcatheter aortic valve. The wire is easy to place, safe to adjust within the ventricle, and the stiffness of the wire facilitates valve tracking through tortuous anatomy. In this study there were no pericardial complications with the use of this dedicated TAVI guidewire.
No takes yet. Share an insight, caveat, or question.
Roy et al. (2013) conducted an observational in Patients referred for TAVI (n=39). Dedicated TAVI guidewire was evaluated on Primary safety endpoint (successful use with no guidewire displacement from the left ventricle). A dedicated TAVI guidewire achieved the primary safety endpoint in 100% of cases (39/39), with no guidewire displacement or pericardial complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: