Key result
Thenar NIRS-derived tissue oxygen saturation correlates with peripheral perfusion changes in critically ill patients.
Why the study?
The significance of near-infrared spectroscopy-derived thenar muscle tissue oxygenation for haemodynamic monitoring after cardiac surgery was unclear.
Does thenar near-infrared spectroscopy (NIRS) correlate with haemodynamic and clinical variables in patients after cardiac surgery?
Observational (n=23)
Does thenar near-infrared spectroscopy (NIRS) correlate with haemodynamic and clinical variables in patients after cardiac surgery?
Thenar NIRS StO2 serves as a non-invasive measure of peripheral rather than global perfusion adequacy after cardiac surgery.
May support thenar NIRS for perfusion monitoring in surgery; leaves open prospective validation before practice change.
We studied the significance of near-infrared spectroscopy (NIRS), for measuring tissue oxygenation (S(t)O(2)) and perfusion adequacy, and thus for haemodynamic monitoring of patients after cardiac surgery. We compared NIRS-derived S(t)O(2) of the thenar muscle to haemodynamic variables, oxygenation indices, temperature, lactate levels and urinary output, in 23 patients in the course of time after cardiac surgery and admission into the intensive care unit. Clinical variables, global haemodynamics and NIRS% total haemoglobin (%HT) and S(t)O(2) in the thenar for up to 18-22 h after admission were measured. The S(t)O(2) declined concomitantly with a rise in the body-finger temperature difference. Cardiac output did not change but mean arterial pressure rose, concomitantly with tapering doses of nitroglycerine, indicative of an increase in vascular tone during recovery from surgery. From all variables, changes in body-finger temperature difference best correlated to changes in S(t)O(2) (r(s)=-0.48, P<0.001). As judged from clinical and haemodynamic correlates, thenar NIRS S(t)O(2) is a non-invasive measure of peripheral rather than global perfusion adequacy, after cardiac surgery. This may help to define the role of thenar NIRS monitoring after cardiac surgery in future studies.
No takes yet. Share an insight, caveat, or question.
Uilkema et al. (2007) conducted an observational in Post-cardiac surgery (n=23). Thenar near-infrared spectroscopy (NIRS) monitoring was evaluated on Correlation between changes in body-finger temperature difference and changes in S(t)O(2) (r(s)=-0.48, p=<0.001). Thenar NIRS-derived tissue oxygen saturation correlated significantly with changes in body-finger temperature difference (r(s)=-0.48, P<0.001), serving as a measure of peripheral perfusion adequacy.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: