Key result
Conduction system pacing-based cardiac resynchronization therapy can reduce device costs by nearly 50% compared with traditional triple-lead systems while mitigating the hemodynamic risks of right ventricular apical pacing.
Why the study?
In limited resource countries like Thailand, CRT under-penetration persists due to high costs and shortage of skilled operators, necessitating cost-effective pacing alternatives.
Does conduction system pacing provide a cost-effective and physiological alternative to traditional pacing and CRT in resource-constrained environments?
Does conduction system pacing provide a cost-effective and physiological alternative to traditional pacing and CRT in resource-constrained environments?
Conduction system pacing offers a cost-effective, physiological alternative to traditional CRT in low-resource settings, potentially reducing device costs by 50%.
Answers are grounded in this paper and cite their sources.
Supports consideration of conduction system pacing CRT in resource-limited settings; leaves open validation in randomized trials.
Background: Right ventricular apical (RVA) pacing often leads to interventricular dyssynchrony and pacing-induced cardiomyopathy. Conduction system pacing (CSP), particularly Left Bundle Branch Area Pacing, provides a physiologic alternative. In Limited Resource Countries (LRCs) like Thailand, Cardiac Resynchronization Therapy (CRT) under-penetration persists due to high costs and a shortage of operators skilled in coronary venous anatomy. Objective: To share the experience and provide clinical update of CSP as a sustainable, cost-effective physiological pacing strategy to improve access to advanced arrhythmia management in resource-constrained environments. Methods: This review explores the implementation of minimalist protocols and CSP-based CRT. Scalability strategies include specialized training programs, device reprocessing, and the establishment of regional longitudinal registries to bridge infrastructure gaps. Results: CSP-based CRT can reduce device costs by nearly 50% compared with traditional triple-lead systems. This modality effectively mitigates the hemodynamic risks of RVA pacing while bypassing the technical and financial barriers of conventional CRT. Discussion: Despite its advantages, CSP adoption requires overcoming infrastructure challenges, specifically the lack of automated remote monitoring. Optimizing clinical outcomes in LRCs necessitates standardized training, robust data collection, and innovative resource management to ensure equitable access to life-saving technology.
No takes yet. Share an insight, caveat, or question.
Chokesuwattanaskul et al. (2026) conducted a review in Bradyarrhythmias and Heart Failure. Conduction system pacing (CSP) vs. Traditional right ventricular apical pacing or biventricular pacing was evaluated. Conduction system pacing-based cardiac resynchronization therapy can reduce device costs by nearly 50% compared with traditional triple-lead systems while mitigating the hemodynamic risks of right ventricular apical pacing.
Synapse has enriched 10 related papers. Consider them for comparative context: