Key result
Post-TAVR repolarization heterogeneity correlates with speckle tracking strain, but not with LVEF.
Why the study?
The relationship between electrocardiographic heterogeneity and speckle tracking strain measures versus LVEF in patients with TAVR-induced conduction abnormalities was unclear.
Do changes in electrocardiographic heterogeneity correlate better with speckle tracking strain measures than with LVEF in patients with TAVR-induced conduction abnormalities?
Observational (n=32)
Single-blind
No
Do changes in electrocardiographic heterogeneity correlate better with speckle tracking strain measures than with LVEF in patients with TAVR-induced conduction abnormalities?
Effect estimate: r=0.4
p-value: p=0.04
In patients with TAVR-induced conduction abnormalities, electrocardiographic heterogeneity correlates with speckle tracking strain measures but not with LVEF, suggesting these parameters may offer additional insights for clinical management.
RWH/TWH correlated with strain but not LVEF after TAVR conduction abnormalities; hypothesis-generating for adjunctive monitoring, prospective studies needed before clinical use.
OBJECTIVE: Transcatheter aortic valve replacement (TAVR) complications include left bundle branch block (LBBB) and right ventricular paced rhythm (RVP). We hypothesised that changes in electrocardiographic heterogeneity would correlate better with speckle tracking strain measures than with left ventricular ejection fraction (LVEF) on transthoracic echocardiogram (TTE) among patients with TAVR-induced conduction abnormalities. METHODS: We reviewed medical records of 446 consecutive patients who underwent TAVR at our institution. Of the 238 patients with 12-lead electrocardiograms (ECGs) that met our inclusion criteria, 58 had pre-TAVR and post-TAVR TTEs adequate for strain assessment. We compared patients who did not have an LBBB or RVP pre-TAVR and post-TAVR (controls, n=11) with patients who developed LBBBs (n=11) and who required RVPs (n=10) post-TAVR. In our study population (n=32, 41% female, mean age 85.8 years), we evaluated QRS complex duration, R-wave heterogeneity (RWH), T-wave heterogeneity (TWH), LVEF, global longitudinal strain (GLS) and mechanical dispersion (MD). RESULTS: TAVR-induced changes on ECG did not correlate with LVEF. TAVR-induced changes in MD and QRS complex duration correlated among all patients (r=0.4, p=0.04). GLS and RWH correlated among RVP patients (r=0.7, p=0.00003). MD and TWH correlated among LBBB patients (r=0.7, p=0.00004). CONCLUSIONS: In this convenience sample of patients with TAVR-induced conduction abnormalities, RWH and TWH correlated with strain measures but not with LVEF. Strain measures, RWH and TWH may offer additional insights for pre-TAVR evaluation and post-TAVR clinical management.
No takes yet. Share an insight, caveat, or question.
Burke et al. (2021) conducted an observational in TAVR-induced conduction abnormalities (LBBB and RVP) (n=32). TAVR-induced left bundle branch block or right ventricular paced rhythm vs. Patients without LBBB or RVP post-TAVR was evaluated on Correlation between TAVR-induced changes in mechanical dispersion and QRS complex duration among all patients (r=0.4, p=0.04). In patients with TAVR-induced conduction abnormalities, changes in R-wave and T-wave heterogeneity correlated with speckle tracking strain measures but not with left ventricular ejection fraction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: