Key result
Locked intramedullary nailing resulted in torsional deviations of more than 15° in 28% of nailed femora and more than 10% of nailed tibiae.
Why the study?
What is the incidence of torsional malalignment following locked intramedullary nailing in adults with diaphyseal femur and tibia fractures?
Observational (n=180)
What is the incidence of torsional malalignment following locked intramedullary nailing in adults with diaphyseal femur and tibia fractures?
Torsional malalignment after intramedullary nailing of the lower limb is common, highlighting the need for improved intraoperative torsional control.
Torsional malalignment after femoral/tibial nailing may predispose to later arthrosis; leaves open whether routine CT surveillance or refined techniques alter outcomes.
Diaphyseal fractures of femora and tibiae in adults are generally stabilised by intramedullary nailing. Nevertheless, this proven technique is burdened by a lack of torsional control intraoperatively. The aim of the study was therefore to analyse the clinical importance of torsional deviations after intramedullary nailing. 180 non-selected patients with diaphyseal fractures according to the A0 classifications 32 (n = 80) and 42 (n = 100) were enrolled in a prospective study. Additionally, the fracture type according to Winquist was defined as well as the soft tissue damage. All fractures were stabilised by locked intramedullary nailing. All patients underwent a torsional analysis by CT or ultrasound after complete fracture healing. In femora an external torsional malalignment of 10-15° was detected in 10 %, of 15-20° in 8.8 % and of more than 20° in 16.3 %. An internal torsional malalignment of 10-15° was noticed in 5 % and of 15-20° in 2.5 %. The healthy contralateral femur served in all cases as intra-individual reference. In the nailed tibiae, external torsional deviations of 10-15° occurred in 10 %, of 15-20° in 2 % and of more than 20° in 4 %. Internal torsional deviations of 10-15° were seen in 5 %, of 15-20° in 3 % and of more than 20° in 1 % of all patients. Torsional deviations of more than 15° concern 28 % of all nailed femora and more than 10 % of all tibiae. Torsional malalignment after intramedullary nailing of the lower limb is of great clinical importance. However, intraoperative torsional control has to be improved.
No takes yet. Share an insight, caveat, or question.
Strecker et al. (2004) conducted an observational in Diaphyseal fractures of femora and tibiae (n=180). Locked intramedullary nailing vs. Healthy contralateral limb was evaluated on Torsional deviations after intramedullary nailing. Locked intramedullary nailing resulted in torsional deviations of more than 15° in 28% of nailed femora and more than 10% of nailed tibiae.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: