Key result
Sinus node recovery time >1500 msec identifies poor sinus node function after rapid atrial pacing.
Why the study?
The relationship of sinus node recovery time after rapid atrial pacing to basal heart rate and its variation in different cardiac conditions was not fully characterized.
Observational (n=66)
An SRT >1500 msec indicates poor sinus node function, though a normal SRT does not definitively exclude sinus node dysfunction.
Answers are grounded in this paper and cite their sources.
Defines normal sinus node recovery time limits; leaves open validation against contemporary pacing protocols and populations.
Sinus node recovery time (SRT) after rapid atrial pacing has been recorded in 66 patients, 28 with coronary heart disease, 11 with advanced AV block, 10 with sick sinus syndrome and 17 with paroxysmal tachyarrhythmias. In patients with a normal functioning sinus node SRT was related to the basal heart rate. On an average SRT was 130% of the basal P-P interval with an upper limit of 160%. In patients with a presumed normal atrial function the mean SRT was found to be 1 080 msec, with an upper limit of 1 500 msec. This corresponds with previously published observations. In all 5 patients examined, beta-receptor blockade (propranolol 5 mg i.v.) prolonged SRT. The prolonged SRT was related to sinus bradycardia. Verapamil (Isoptin 5 mg i.v.) had no effect on SRT in the 7 patients examined. The observation of an SRT of more than 1 500 msec indicates a poor sinus node function. Recording of a normal SRT, however, cannot exclude a sinus node dysfunction, as normal SRT is occasionally found even in patients with a clinically proved dysfunction.
No takes yet. Share an insight, caveat, or question.
Grendahl et al. (1975) conducted an observational in Sinus rhythm and dysrhythmias (n=66). Rapid atrial pacing was evaluated on Sinus node recovery time (SRT).
Synapse has enriched 10 related papers. Consider them for comparative context: