This article examines the effects of acid diffusion in APEX-E through the quantitative modeling of resist top loss in unexposed samples due to acid diffusion from a top-to-top contact bake with an exposed sample. Top-loss measurements are reported for 90 and 95 °C postexposure bake (PEB) temperatures ranging from 60 to 360 s bake times, resulting in 0.12 and 0.29 μm top loss, respectively, after 360 s PEB times. Results of systematically changing the diffusion constant, the kinetic reaction rates, and the deprotection level for dissolution in a Fickean diffusion model show that this model cannot account for the experimental observations. A better fit of the data and a near linear top-loss dependence with bake time are obtained with a deprotection dependent diffusion model, suggesting nonlinear diffusion mechanisms are important in modeling lithographic performance in positive deep ultraviolet resists.
No takes yet. Share an insight, caveat, or question.
Zúñiga et al. (1995) studied this question.