Key result
Digital echocardiography shows diagnostic concordance with videotape review in ~88% of cases.
Why the study?
Limited information is available on the accuracy of clinically compressed digitised echocardiographic examinations, which is important for patient safety.
Does clinically compressed digital echocardiography provide comparable diagnostic accuracy to videotape review in patients undergoing transthoracic echocardiograms?
Observational (n=520)
No
Does clinically compressed digital echocardiography provide comparable diagnostic accuracy to videotape review in patients undergoing transthoracic echocardiograms?
Answers are grounded in this paper and cite their sources.
Clinically compressed digital echocardiography is a safe and accurate alternative to videotape review, with a low rate of clinically important diagnostic errors.
INTRODUCTION: Digital storage of echocardiographic data offers logistical advantages over videotape archival. However, limited information is available on the accuracy of clinically compressed digitised examinations, an important consideration for patient safety. MATERIALS AND METHODS: Transthoracic echocardiograms of 520 consecutive patients were prospectively acquired digitally and on videotape. Two echocardiologists, in consensus, reported studies in both formats sequentially. Using the videotape as a reference, the significance of any reported differences was graded from both imaging and clinical standpoints, and the reasons for these differences identified. RESULTS: From an imaging perspective, differences between digital and videotaped studies were absent or minor in 459 cases (88%), fairly significant in 55 (11%) and very significant in 6 (1%). The main reasons for the observed differences were inadequate acquisition of optimal views (59%), an insufficient number of acquired cardiac cycles (25%) and suboptimal image quality (9%). These differences were considered to be of possible or definite clinical importance in 21 (4%) and 8 (2%) cases, respectively. In multinominal logistic regression models, the only independent predictor of significant difference between digitised and videotaped images was study complexity. Regardless of case complexity, most diagnostic errors arising from digital review were attributable to technical failure rather than observer error. CONCLUSIONS: The potential for important errors arising from exclusive reporting of clinically compressed digital echocardiograms is small. Digital echocardiography, as practiced in a routine clinical setting, offers a patient-safe alternative to videotape review.
No takes yet. Share an insight, caveat, or question.
Poh et al. (2007) conducted an observational in Patients referred for transthoracic echocardiography (n=520). Clinically compressed digital echocardiography vs. Videotape review was evaluated on Complete or near-complete concordance between digital and videotaped echocardiographic images. Clinically compressed digital echocardiography demonstrated complete or near-complete diagnostic concordance with videotape review in 88% of cases, with highly significant differences in only 1%.
Synapse has enriched 10 related papers. Consider them for comparative context: