Key result
Robot-assisted totally endoscopic mitral valve repair using a novel atrial retractor was successfully performed, with postoperative echocardiography confirming the absence of mitral insufficiency.
Case Report (n=1)
No
This case report demonstrates the successful first use of robot-assisted totally endoscopic mitral valve repair with a novel atrial retractor in Japan.
Answers are grounded in this paper and cite their sources.
Successful in single case; hypothesis-generating for robotic mitral techniques and requires prospective validation before wider use.
This case report presents the first robot-assisted totally endoscopic mitral valve plasty in Japan. A 54-year-old woman was found by echocardiography to have grade III mitral valve regurgitation because of prolapse of the posterior leaflet. Surgical repair was performed using the da Vinci Surgical System. For the totally endoscopic mitral valve repair, a right-sided approach was used through four ports. A transthoracic aortic cross-clamp and novel flexible port access retractor were inserted through a 5-mm skin incision. Quadrangular resection of the posterior leaflet was performed, and an annuloplasty band was placed into the atrium. Resection of the valve segment took 13 min, and band implementation, 45 min. The total pump time was 197 min and the aortic cross-clamp time, 117 min. Postoperative echocardiography confirmed the absence of mitral insufficiency.
No takes yet. Share an insight, caveat, or question.
Ishikawa et al. (2009) conducted a case report in Grade III mitral valve regurgitation (n=1). Robot-assisted totally endoscopic mitral valve repair was evaluated on Postoperative mitral insufficiency. Robot-assisted totally endoscopic mitral valve repair using a novel atrial retractor was successfully performed, with postoperative echocardiography confirming the absence of mitral insufficiency.
Synapse has enriched 10 related papers. Consider them for comparative context: