Key result
Point-of-care cTnI testing cuts turnaround time by >50% compared to off-site hs-cTnT testing.
Why the study?
Delays in off-site high-sensitivity cardiac troponin T testing at pediatric hospitals may impair timely detection of myocardial injury.
Does on-site point-of-care whole blood cTnI testing improve turnaround times and accurately triage myocardial injury compared to off-site hs-cTnT testing in a pediatric hospital?
Observational
No
Does on-site point-of-care whole blood cTnI testing improve turnaround times and accurately triage myocardial injury compared to off-site hs-cTnT testing in a pediatric hospital?
On-site point-of-care whole blood cardiac troponin testing significantly reduces turnaround times and can rapidly confirm significant myocardial injury, serving as a viable interim triage strategy for pediatric hospitals lacking on-site high-sensitivity assays.
Answers are grounded in this paper and cite their sources.
May accelerate troponin results in acute care; leaves open whether POC cTnI can substitute for hs-cTnT in routine diagnosis.
BACKGROUND: The importance of offering on-site cardiac troponin (cTn) testing at pediatric hospitals may be underappreciated. We developed a rapid rule-in process for myocardial injury at a pediatric hospital experiencing delays in off-site high-sensitivity cardiac troponin T (hs-cTnT) testing. METHODS: Collect-to-verify turnaround times (TATs) for off-site testing were reviewed. Pre-analytic changes to improve TATs were devised, implemented and evaluated, after which a new analyzer was selected and evaluated for on-site cTn testing. Performance of the new analyzer's assay was compared to the off-site hs-cTnT assay, and post go-live TATs for on-site testing were assessed. RESULTS: Median collect-to-verify TAT for short turnaround-time (STAT) priority off-site plasma hs-cTnT testing was 104 min, with 35% of orders having a TAT >120 min. Eliminating serum separator tubes and requiring a separate plasma separator tube did not significantly reduce TATs. A QuidelOrtho Triage® MeterPro whole blood cardiac troponin I (cTnI) assay was implemented to "triage" time-critical and STAT priority specimens collected for off-site hs-cTnT testing. Elevated cTnI (≥0.02 µg/L) had a sensitivity of 91% for clear elevations in hs-cTnT (≥53 ng/L) but a 0% sensitivity for modest elevations (5 to 13 ng/L, 14 to 52 ng/L). An interpretive comment was auto-appended to cTnI results indicating that clinicians should wait for the hs-cTnT result if cTnI was normal. Median collect-to-verify TAT for on-site cTnI testing was <50% the TAT for off-site hs-cTnT testing. CONCLUSIONS: On-site point-of-care whole blood cTn testing can rapidly confirm significant or late-presenting myocardial injury. Combined with simultaneous off-site high-sensitivity cardiac troponin (hs-cTn) testing, this workflow is a viable interim solution for pediatric hospitals without on-site hs-cTn testing.
No takes yet. Share an insight, caveat, or question.
Koning et al. (2024) conducted an observational in Myocardial injury. On-site point-of-care whole blood cardiac troponin I (cTnI) testing vs. Off-site high-sensitivity cardiac troponin T (hs-cTnT) testing was evaluated on Collect-to-verify turnaround time (TAT). On-site point-of-care whole blood cTnI testing reduced median turnaround time to <50% of off-site testing and demonstrated 91% sensitivity for clear hs-cTnT elevations (≥53 ng/L).
Synapse has enriched 10 related papers. Consider them for comparative context: