Key result
A 3-hole DHS side plate shows similar failure rates compared to a 4-hole plate.
Why the study?
The 4-hole DHS side plate is standard for extracapsular hip fractures but has disadvantages; biomechanical data suggest 3-hole plates may be adequate, including for unstable fractures.
Does 3-hole DHS side plate fixation provide comparable outcomes to 4-hole DHS side plate fixation in patients with extracapsular hip fractures?
Observational (n=72)
Does 3-hole DHS side plate fixation provide comparable outcomes to 4-hole DHS side plate fixation in patients with extracapsular hip fractures?
Three-hole DHS plates offer comparable outcomes to 4-hole plates for extracapsular hip fractures, with potentially less blood loss.
Answers are grounded in this paper and cite their sources.
3-hole DHS yields comparable outcomes to 4-hole in this retrospective cohort even for unstable fractures; leaves open adoption pending randomized trials.
Introduction: Dynamic hip screw fixation (DHS) with a 4-hole side plate and 4 bi-cortical screws is considered by many to be the standard implant for extracapsular hip fractures. The 4-hole side plate, however, has several disadvantages including longer incision, increase in operating time, bleeding and increased wound morbidity. Biomechanical studies have shown that most of the force in a 4-hole DHS fixation is borne by the proximal three screws. This study (specifically) compares the outcome of fixation using 3-hole and 4-hole DHS in extracapsular hip fracture fixations (with the hypothesis being that 3-hole plate is adequate even in unstable intertrochanteric fractures. Patients and Methods: A total of 72 consecutive patients who had DHS fixation with either a 3 hole or 4 hole DHS side plate and who were either directly operated or supervised by a single consultant were recruited. Fractures were classified using the AO fracture classification system as stable (AO/OTA 31A1–31A2.1) and unstable (31A2.2–31A3.3 subtypes) for ease of comparison. Failure was defined as metalwork breakage, nonunion, screw cut-out or pull out or any other complications of bone healing requiring a revision. Results: A total of 23 patients (68.1%) were female, whereas 49 patients (31.9%) were male. Fractures in 33 patients were classified as stable with the (AO/OTA 31A1–31A2.1) and unstable in 39 patients with (31A2.2–31A3.3 subtypes). Thirty-three (45.8%) patients had fixation with 3-hole side plate, whereas 39 (55.2%) patients had fixation with 4-hole side plate. In the 3 hole group, 17 patients had stable fractures, whereas 16 patients had unstable fracture configuration while in the 4-hole DHS side plate group, 16 patients had stable fracture configuration, whereas 23 patients had unstable fracture. The mean change in hemoglobin was lower for the 3-hole DHS group (3 hole-6.64 g/l versus 4Hole 12.41 g/l) ( t = 1.732, P = 0.090, P ≤ 0.05). One patient in each group also had metalwork failure with screw cut-out through the head and the other being (screw breakage) complete failure of the screw necessitating conversion to total hip arthroplasty. Conclusion: Three-hole DHS plate offers comparable outcome with its 4-hole counterpart even with unstable intertrochanteric fractures, with slightly less blood loss and smaller scars.
No takes yet. Share an insight, caveat, or question.
Akinyemi et al. (2022) conducted an observational in Extracapsular hip fractures (n=72). 3-hole DHS side plate vs. 4-hole DHS side plate was evaluated on Failure (metalwork breakage, nonunion, screw cut-out or pull out or complications requiring revision). Fixation with a 3-hole DHS side plate yielded similar failure rates and a trend toward lower mean hemoglobin drop compared to a 4-hole plate.