Key result
FEM-SMART technique achieves 100% technical success in narrow-lumen thoracoabdominal aortic aneurysm repair.
Why the study?
Total transfemoral thoracoabdominal aortic aneurysm repair may be challenging in patients with narrow aortic lumens, necessitating novel techniques to facilitate target vessel catheterization.
Is the FEM-SMART technique feasible and safe for thoracoabdominal aortic aneurysm repair in patients with narrow aortic lumens?
Case Report (n=7)
Is the FEM-SMART technique feasible and safe for thoracoabdominal aortic aneurysm repair in patients with narrow aortic lumens?
Answers are grounded in this paper and cite their sources.
The FEM-SMART technique appears feasible and safe for total transfemoral thoracoabdominal aortic aneurysm repair in patients with narrow aortic lumens, achieving 100% technical success in an initial small cohort.
Total transfemoral approach may be challenging in patients with narrow aortic lumens. We describe a novel total femoral staggered multibranch thoracoabdominal aortic aneurysm repair technique (FEM-SMART) to facilitate target vessel catheterization in this population. FEM-SMART is performed using a standard off-the-shelf multibranch stent graft via a total transfemoral approach. The endograft is partially deployed to the level of the celiac axis directional branch, which is selectively catheterized via contralateral femoral access using a steerable sheath. Subsequently, staggered endograft deployment, sequential catheterization of directional branches, and target vessel stenting are performed, starting with the superior mesenteric artery, followed by the renal arteries. The infrarenal segment of the endograft is then partially deployed and catheterized using the steerable sheath, which is reformed and used for catheterization and stenting of the celiac axis. Diameter-reducing ties are released, and the repair is completed in a standard fashion. Seven patients (5 males; median age, 76 years; interquartile range, 56-83 years) were treated using FEM-SMART. Technical success was 100%. There were no target vessel instabilities or major complications at a median follow-up of 2 months (interquartile range, 1.5-4.5 months). These results support FEM-SMART as a feasible technique that enables a total transfemoral approach in patients with narrow aortic lumens.
No takes yet. Share an insight, caveat, or question.
Park et al. (2025) conducted a case report in Thoracoabdominal aortic aneurysm with narrow aortic lumens (n=7). FEM-SMART (femoral staggered multibranch thoracoabdominal aortic aneurysm repair technique) was evaluated on Technical success. The FEM-SMART technique for thoracoabdominal aortic aneurysm repair in patients with narrow aortic lumens achieved 100% technical success with no major complications at 2 months.
Synapse has enriched 10 related papers. Consider them for comparative context: