Fluorine-containing phases are closely linked to electrolyte decomposition, interphase formation, and failure processes in Li-ion batteries, yet their spatially resolved analysis in composite cathodes remains difficult. Here, laser-induced XUV spectroscopy (LIXS) was used to map fluorine- and lithium-related emission lines in composite lithium cobalt oxide cathodes (LCO). The study used the fluorine emission line at λ = 12.72 nm and the lithium emission line at λ = 13.42 nm and applied them to pristine, formed, aged, and failed LCO cathodes. A matrix-matched calibration using seven Li metal oxide cathode materials at three fluorine levels showed increasing fluorine-related intensity within each matrix, along with pronounced matrix specificity and dispersion. This indicated that fluorine quantification in composite cathodes is influenced by matrix effects, non-thermal equilibrium plasma behavior, and heterogeneity of polyvinylidene fluoride (PVDF) containing fluorine-bearing phases. In the mapped cathodes, the F/Li intensity ratio provided the most sensitive descriptor of degradation, showing increasing imbalance and greater spatial heterogeneity from pristine to failed electrodes. LIXS is therefore advantageous for comparative mapping of light-element/halogen heterogeneity in battery cathodes, where reliable fluorine quantification across chemically distinct composite materials remains intrinsically difficult.