Answers are grounded in this paper and cite their sources.
A high-performance liquid chromatographic method with amperometric detection has been developed for the determination of the diuretic bumetanide using a microBondapak C18 column. The mobile phase consists of a 50:50 acetonitrile-water mixture containing 5mM KH2PO4-K2HPO4 (pH 4.0). The compound is monitored at +1350 mV with an amperometric detector equipped with a glassy carbon working electrode. A liquid-liquid or solid-liquid extraction is done prior to chromatographic analysis in order to avoid the interferences found in the urine matrix. The percentages of recovery obtained are 71%+/-1% for liquid-liquid extraction and 84.2%+/-0.7% for solid-liquid extraction. The method developed has a linear concentration range from 50 to 499 ng/mL with a reproducibility in terms of relative standard deviation of 1.73% and 3.85% for a concentration level of 70 ng/mL and 237 ng/mL, respectively, and a detection limit of 0.25 ng/mL (3:1 signal-to-noise ratio). The method is applied to the determination of bumetanide in pharmaceutical formulations and urine obtained from hypertensive patients and healthy volunteers after the ingestion of a therapeutic dose of Fordiuran (1 mg bumetanide).
No takes yet. Share an insight, caveat, or question.
Legorburu et al. (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: