Answers are grounded in this paper and cite their sources.
The paper presented here deals with the investigations of orthophosphates (Q0) containing none or differing amounts of meta-(Q2) and diphosphate phases (Q1) for the use of 3-dimensional printing process in order to create porous, bioactive, nonloadbearing bone replacement scaffolds. The main ceramic phase in all cases is Ca10[K/N(PO4)7 hereinafter called 401545(100) consisting of 99,9% Q0 and 0,1% Q1-phase. The other phosphate ceramics i) 401545(40) consists of 75% Q0-phase, 22% Q1-phase and 4% Q2-phase ii) 401545(15) consists of 65% Q0-phase, 33% Q1-phase and 2% Q2-phase iii) 401545consists of 56% Q0-phase, 40% Q1-phase and 4% Q2-phase. The in-house produced ceramics where crushed and sieved to achieve particles of irregular shape in the range of 45-90µm. These powders show a quite good flowability and were used to generate cylindrical samples with a diameter of 5,5mm and a height of 11mm via 3-dimensional printing using a R1 printer from ProMetal company (USA). After drying the samples at T=125°C for 48 hours they were sintered at temperatures according to the thermal analysis results in the range of 900°C up to 1300°C. Afterwards the porosity, the linear shrinkage and the compressive strength were determined.
No takes yet. Share an insight, caveat, or question.
Dombrowski et al. (2012) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: