Answers are grounded in this paper and cite their sources.
This paper presents the results of radiation conditions analysis of the detector modules of diagnostic tool «Divertor Neutron Flux Moni-tor» (DNFM) of the ITER tokamak-reactor. Diagnostic tool is designed to measure neutron yield and fusion power of ITER. At the final design stage of the DNFM system it was decided to change the location of the detector modules of diagnostic tool, which required a refinement of calculations of the energy distribution of neutron flux in the area of the detectors, the fission rate of uranium in the fission chambers of the DNFM and the Green’s function of fission rate. A study of the response of the system to the neutron yield spatial distribution of 500 MW DT ITER plasma was carried out. Modeling is performed with the three-dimensional model of ITER tokamak-reactor using MCNP code. The expected performance characteristics of DNFM system based on the results of neutron transport analysis and requirements to diagnostics from ITER Organization have been confirmed.
No takes yet. Share an insight, caveat, or question.
Kovalev et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: