This is the authors' abstract. We don't add key points for this paper.
This article presents a strain measurement method using a singlemode‐multimode‐singlemode fiber structure sensor and an optical time domain reflectometer. A strain measurement range of 0–1000 με can be achieved with a resolution of better than 10 με. Using this method, a quasi‐distributed strain measurement can be carried out which is useful for a bridge or a civil structure strain monitoring.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Hatta et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: