Answers are grounded in this paper and cite their sources.
Hydrogen peroxide (H 2 O 2 ), an important reactive oxygen species, is widely used in disinfection and food processing. It is also a marker for many diseases and is closely related to human health. In this experiment, the electrospinning technique was used to derive a copper/zirconium carbon nanofiber (CuZr-CNF) from metal-organic framework (MOF) for electrochemical monitoring of H 2 O 2 , which demonstrate a wide linear range from 50 to 21600 μM and high sensitivity. The linear range reaches four orders of magnitude, and the detection limit is 3.67 μM. At the same time, we also conducted a colorimetric monitoring of H 2 O 2 using MOF raw materials. H 2 O 2 was monitored through the color reaction between H 2 O 2 and 3,3',5,5'-Tetramethylbenzidine (TMB). In actual sample tests using this “raw material-derivative dual-mode” probe, the recovery rate ranged from 90.37% to 112.46%, confirming its potential for detecting H₂O₂ in real-world applications.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: